UMG 20CM

RCM and energy measurement device in a single unit

  • 20 current measurement channels +/- 0.5 %
  • 4 voltage measurement channels +/- 0.5 %
  • Internal RS485 interface (Modbus as Slave)
  • 20 LEDs – One LED for each current channel (Green = o.k., Yellow = Warning; Red = Nominal current exceed)
  • Measurement range of operation current with burden up to 63 A with closed or split core current transformers (standard measured values: V, A, kW, kVA, kVar, kWh)

The system for smart people

  • Compact nature of the system
  • Can be retrofitted to existing systems
  • Modbus RTU directly on board
  • State indication per channel (LEDs)
  • Name stored per channel in the measurement device
  • Wide range power adapter (90 – 276 V ... AC / DC)
  • Integration in the GridVis® software
  • Diverse current transformer variants for the individual application
  • Measurement variants:
    • Three-phase and single-phase energy measurement
    • RCM measurement three-phase and single-phase
  • High sampling rate 20,000 Hz
  • Current transformer connection monitoring (i.e. wire break will be detected)
  • Harmonics analysis up to 63rd harmonic via analysis channel
  • Saving of minimum and maximum values with time stamp
  • Standard measured values: V, A, kW, kVA, kVar, kWh (variable list)
  • Scalability of the system
Fig.: Operating current and RCM fault current monitoring
Fig.: Operating current and RCM fault current monitoring

Power supply without drop-outs

  • Permanent monitoring and logging of processes in TN-S or TN-C-S systems
  • Simple parameterisation and operation of the RCM measurement
  • Automatic reporting in the event of problems enables a rapid initiation of countermeasures
  • Comprehensive diagnostics increase safety and efficiency of a company
Fig.: Message before shut-down - an objective of residual current monitoring
Fig.: Message before shut-down - an objective of residual current monitoring

Alarms before failures (preventative residual current analysis)

  • Faults arising will be detected in good time
  • Monitoring, evaluation and reporting of creeping increases in residual currents (e.g. triggered by insulation faults and operating currents for system parts or loads being too high)
  • Reduction of downtimes

Sensors for energy management

  • Energy data of a large number of loads can be acquired and passed to a database with ease
  • Automatic reading out and saving of the measured values and data saved in the measurement devices as well as the exceedance of parameterised threshold values 
  • Channel-specific measured values of the current monitoring devices can be displayed via the GridVis® software
    • The progression of measured values is visualised graphically
    • Display of warnings or fault messages possible, e.g. via the topology views
    • Associated message texts can be freely configured for this
    • Automatic sending of an email in the event of operational or fault messages
    • Remote monitoring of the entire system is possible via internet
    • Residual current and operational current monitoring devices can be parameterised via GridVis® (Modbus)
  • The evaluation and saving of data in central databases is implemented via the GridVis® software
  • The greater the scope of information, the more accurate the determination of savings potentials
  • Energy optimisation offers a higher, more economical savings potential (ISO 50001)
Fig.: Read-out, analysis and saving of energy data
Fig.: Read-out, analysis and saving of energy data

Your benefits

The intelligent system solution

  • Early warning with system failures
  • Avoidance of costly and hazardous system downtimes; the availability of systems is increased
  • Localisation of individual faulty feeders, reduced work when troubleshooting
  • Early detection of an overloading of the N conductor and critical residual currents, resulting in increased fire safety
  • Through parameterisation of the system in new condition and constant monitoring, all changes to the system state after the point of commissioning can be detected
  • Fulfilment of the safety criteria "RCM residual current monitoring" in data centres
  • Convenient monitoring and parameterisation solution with GridVis® software
  • Operating current acquisition of all relevant consumers as a basis for an energy management system (EnMS)
Fig.: Constant processes and highly sensitive applications such as data centres, are based on RCM monitoring.
Fig.: Constant processes and highly sensitive applications such as data centres, are based on RCM monitoring.

Survey about Janitza

To optimize our services and offers we would like to ask you just one simple question.

It's completely anonymous and takes less than a minute to answer.

Let's go!

How did you learn
about our company?

Fields marked with an * are mandatory.

Thank you for your participation!

We'll be able to improve our services and offers upon your answers.

Close survey

Do you want to return to our survey later?

Yes, I'll answer it later
No, don't ask me again