Functions and features

Get a general overview of the most important functions of the UMG 96RM.

Multifunctional power analyzer

  • Particular advantages

    • Compact construction saves space and costs during installation
    • Seamless and sustained recording thanks to large measured data memory or via the online data acquisition (e.g. GridVis®-Service)
    • High data security and redundancy
    • Comprehensive communications options and protocols
    • Multifaceted, pre-defined reports for power quality and energy consumption analysis (via GridVis®-Service)
    • Simple report generation at the press of a button or automatically in accordance with defined time plans
    • Precision measurement results provide an effective infrastructure as well as high production availability
    • Generic Modbus profile: Arbitrary Modbus-capable devices and systems from other manufacturers can be incorporated and visualised in the monitoring solutions
    • Long-term availability of the measurement devices guarantees simple retrofitting with system expansions
  • Energy data acquisition & load profile

    • Detailed acquisition of the energy data and the load profile
    • More transparency in energy supply through energy analyses
    • Safer design of the power distribution systems
    • Fig.: Load profiles are the basis for energy management
  • Cost centre analysis

    • Determination of energy costs
    • Breakdown and allocation of energy consumers
    • Fig.: Cost centre analysis
  • Energy management systems (ISO 50001)

    • Continuous increase in energy efficiency
    • Cost reduction
    • UMG 96RM series multifunctional power analyzers are an important part of energy management systems
  • Transparency of energy supply

    • More transparency through a multi-stage, scalable measurement system
    • Acquisition of individual events through continuous measurement with high resolution
    • Fig.: Transparency of energy supply
  • Power quality monitoring

    • Notification of inadequate power quality
    • Introduction of measures to address network problems
    • Prevention of production downtimes
    • Significantly longer service life for equipment
    • Improved sustainability
    • Fig.: Power quality monitoring (Harmonics analysis for the current up to 40th order harmonics)
  • Measurement accuracy of 0.2 % (V), kWh class = 0.5

    • High sampling rate at 21.3 kHz
    • Reliable measurement accuracy of 0.2 % (V)
    • Effective energy class (kWh): 0.5
  • Energy meter with 7 tariffs, effective and reactive energy

    • Energy measurement in 4 quadrants, each with 7 tariffs for effective and reactive energy
    • Safe and precise acquisition of operational values for individual electrical loads
  • Communication options: Ethernet, Profibus, Modbus, M-Bus ...

    • Numerous interfaces and protocols, guaranteeing an easy system connection (energy management system, PLC, SCADA, BMS)
  • Harmonics analyzer

    • Harmonics analysis up to 40th harmonic
    • Information about power quality, grid disturbances and possible "network polluters"
  • Pluggable screw terminals

    • Convenient installation even where spaces are tight
    • Fig.: Pluggable screw terminals for easy connection
  • Backlight

    • Large, high-contrast LCD display with backlighting
    • Very good readability and intuitive operation, even in poor lighting conditions
    • Fig.: LCD Display backlight
  • Basic device

    • RS485 interface with Modbus protocol and 2 digital outputs enable quick and low-cost monitoring of power quality and energy consumption