Supply voltage external
Extern 24 V DC, PELV
5231003
Thanks to the compact module design, the UMG 801 can be expanded in a variety of ways, for example to up to 92 current measurement inputs or 144 digital inputs.
The 800-CT8-A current measuring module extends the base device with 8 additional current measuring
channels for each module attached. The modules can be connected using a click system with no
external cabling between the base device and the current measuring modules.
You can use the 800-CT8-LP current measuring module to expand the basic device by 8 additional current measuring channels for low power current transformers. The module takes up very little space with just one 1 sub-unit. The modules are connected via the click system. You do not need any cables connecting the basic device and module.
Low power current transformers offer numerous advantages over conventional transformers. For example, they do not have to be short-circuited during
installation or servicing, which eliminates the need for transformer disconnect terminals. This saves a lot of space in the switchboard cabinet and saves the cost of disconnect terminals and installation.
The 800-CT24 current measuring module adds 24 low-power current measurement inputs per module to the basic device. The modules are connected via the 800-CON-RJ45 module.
The 800-DI14 expansion module has 14 additional digital inputs. Use the click system to connect the modules to the base system.
Remote measurement points can be connected quickly and easily using the 800-CON transfer module. This involves docking the transition module to the base device and connecting it to a transition module located up to 100 m away using a cable.
The expansion modules can be connected to the second transition module to take measurements remotely and record the data.
An 800-CON module does not require a module slot.
There is a limit to the number of modules that can be connected to a UMG 801. This limit is expressed in terms of module slots, which help to determine how many modules can be connected at any one time. The limit depends on the software used and does not correspond to any physical connections.
The UMG 801 has 10 of these module slots and each module requires the number of slots defined for this module. This number can vary from module to module. For example, the basic device can be expanded to up to 92 current measuring channels or 144 digital inputs when using the right module.
Supply voltage external
Extern 24 V DC, PELV
5231003
5231230
5231234
5231210
5231242
5231214
5231212
More information
Events
External content from Pardot
To protect your personal data, the connection to Pardot has been blocked. Click on the button to unblock the Pardot form. By unblocking the form, you accept Pardot's privacy policy. You can find more information about Pardot's data protection in our privacy policy. Show external content